- Universal coding with RFID technology
- 1 x connector plug M12, 8-pole
- Series-wiring up to 31 components
- with latching
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- 3 different directions of actuation
- Door stop with magnetic latching
- Connection terminal or plug connection
- Suitable for series-wiring
Ordering data
| Product type description | RSS16-SD-R-ST8H |
| Article number (order number) | 103004369 |
| EAN (European Article Number) | 4030661456966 |
| eCl@ss number, Version 9.0 | 27-27-24-03 |
| eCl@ss number, Version 11.0 | 27-27-24-03 |
Approval - Standards
| Certificates | TÜV cULus EAC FCC IC |
General data
| Standards | IEC 60947-5-3 |
| general information | Universal coding |
| Coding level according to ISO 14119 | Low |
| Active principle | RFID |
| Housing construction form | Block |
| Installation conditions (mechanical) | not flush |
| Sensor topology | Sensor for series wiring |
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Active area | Glass-fibre, reinforced thermoplastic |
| Gross weight | 0.2 g |
| Time to readiness, maximum | 2,000 ms |
| Reaction time, maximum | 100 ms |
| Duration of risk, maximum | 200 ms |
General data - Features
| Serial diagnostics | Yes |
| Latching | Yes |
| Diagnostic output | Yes |
| Short circuit detection | Yes |
| Short-circuit recognition | Yes |
| Series-wiring | Yes |
| Safety functions | Yes |
| Cascadable | Yes |
| Integral System Diagnostics, status | Yes |
| Number of LEDs | 2 |
| Number of semi-conductor outputs with signaling function | 1 |
| Number of fail-safe digital outputs | 2 |
| Number of Series-wiring of sensors | 31 |
Safety appraisal
| Standards | EN ISO 13849-1 IEC 60947-5-3 EN 62061 IEC 61508 | |
| Performance level, up to | e | |
| Control category to EN13849 | 4 | |
| PFH-value | 6.30 x 10⁻¹¹ /h | |
| 3 | |
| Mission Time | 20 Year(s) |
Mechanical data
| Actuating panels | front side rear from head |
| Active area | lateral front side cover-side |
| Hysteresis (Switch distance), maximum | 2 mm |
| Repeat accuracy R R | 0.5 mm |
| Mounting | 2 x M5, Cylinder head screw |
| Tightening torque of nuts, maximum | 2 Nm |
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance | 15 mm |
| Ensured switch distance ON Sao | 5 mm |
| Ensured switch distance OFF Sar | 30 mm |
Mechanical data - Connection technique
| Terminal Connector | Connector M12, 8-pole |
| Note | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current |
Mechanical data - Dimensions
| Length of sensor | 91 mm |
| Width of sensor | 52 mm |
| Height of sensor | 30 mm |
Ambient conditions
| Degree of protection | IP65 to EN 60529 IP66 to EN 60529 IP67 to EN 60529 |
| Ambient temperature, minimum | -25 °C |
| Ambient temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Storage and transport temperature, maximum | +85 °C |
| Restistance to shock | 30 g / 11 ms |
| Protection rating | 0 |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC |
| Rated impulse withstand voltage Uimp | 0.8 kV |
| Overvoltage category | III |
| Degree of pollution to VDE 0100 | 3 |
Electrical data
| Voltage type | DC (direct current) |
| No-load supply current I0 | 100 mA |
| Rated operating voltage, minimum | 20.4 VDC |
| Rated operating voltage, maximum | 26.4 VDC |
| Operating current | 2,100 mA |
| Required rated short-circuit current to EN 60947-5-1 | 100 A |
| Switching frequency, approx. | 1 Hz |
Electrical data - Fail-safe digital outputs
| Rated operating current (safety outputs) | 1,000 mA |
| Output current, (fail-safe output), maximum | 1 A |
| Versions | p-type |
| Voltage drop Ud, maximum | 1 V |
| Current leakage Ir | 0.5 mA |
| Voltage, Utilisation category DC12 | 24 VDC |
| Current, Utilisation category DC12 | 1 A |
| Voltage, Utilisation category DC13 | 24 VDC |
| Current, Utilisation category DC13 | 1 A |
Electrical data - Diagnostic output
| Operating current | 150 mA |
| Versions | p-type |
| Voltage drop Ud, maximum | 2 V |
Electrical data - Electromagnetic compatibility (EMC)
| Interfering radiation | IEC 61000-6-4 |
| EMC rating | IEC 60947-3 |
Status indication
| Note (LED switching conditions display) | Multi-coloured LED: Green, Red LED yellow: Operating condition LED green: Supply voltage LED red: Fault |
Scope of delivery
| Included in delivery | Actuators must be ordered separately. |
Accessory
| Recommendation (actuator) | RST16-1-R |
| Recommended safety switchgear | PROTECT PSC1 SRB-E-301ST SRB-E-201LC |