- Universal coding with RFID technology
- 1 x connector plug M12, 8-pole
- Series-wiring up to 31 components
- without latching
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- 3 different directions of actuation
- Door stop with magnetic latching
- Connection terminal or plug connection
- Suitable for series-wiring
Ordering data
| Product type description | RSS16-SD-ST8H | 
| Article number (order number) | 103006685 | 
| EAN (European Article Number) | 4030661456959 | 
| eCl@ss number, Version 9.0 | 27-27-24-03 | 
| eCl@ss number, Version 11.0 | 27-27-24-03 | 
Approval - Standards
| Certificates | TÜV cULus EAC FCC IC | 
General data
| Standards | IEC 60947-5-3 | 
| general information | Universal coding | 
| Coding level according to ISO 14119 | Low | 
| Active principle | RFID | 
| Housing construction form | Block | 
| Installation conditions (mechanical) | not flush | 
| Sensor topology | Sensor for series wiring | 
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing | 
| Active area | Glass-fibre, reinforced thermoplastic | 
| Gross weight | 250 g | 
| Time to readiness, maximum | 2,000 ms | 
| Reaction time, maximum | 100 ms | 
| Duration of risk, maximum | 200 ms | 
General data - Features
| Serial diagnostics | Yes | 
| Diagnostic output | Yes | 
| Short circuit detection | Yes | 
| Short-circuit recognition | Yes | 
| Series-wiring | Yes | 
| Safety functions | Yes | 
| Cascadable | Yes | 
| Integral System Diagnostics, status | Yes | 
| Number of LEDs | 2 | 
| Number of semi-conductor outputs with signaling function | 1 | 
| Number of fail-safe digital outputs | 2 | 
| Number of Series-wiring of sensors | 31 | 
Safety appraisal
| Standards | EN ISO 13849-1 IEC 60947-5-3 EN 62061 IEC 61508 | |
| Performance level, up to | e | |
| Control category to EN13849 | 4 | |
| PFH-value | 6.30 x 10⁻¹¹ /h | |
| 
 | 3 | |
| Mission Time | 20 Year(s) | 
Mechanical data
| Actuating panels | front side rear from head | 
| Active area | lateral front side cover-side | 
| Hysteresis (Switch distance), maximum | 2 mm | 
| Repeat accuracy R R | 0.5 mm | 
| Mounting | 2 x M5, Cylinder head screw | 
| Tightening torque of nuts, maximum | 2 Nm | 
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance | 15 mm | 
| Ensured switch distance ON Sao | 12 mm | 
| Ensured switch distance OFF Sar | 30 mm | 
Mechanical data - Connection technique
| Terminal Connector | Connector M12, 8-pole | 
| Note | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current | 
Mechanical data - Dimensions
| Length of sensor | 91 mm | 
| Width of sensor | 52 mm | 
| Height of sensor | 30 mm | 
Ambient conditions
| Degree of protection | IP65 to EN 60529 IP66 to EN 60529 IP67 to EN 60529 | 
| Ambient temperature, minimum | -25 °C | 
| Ambient temperature, maximum | +70 °C | 
| Storage and transport temperature, minimum | -25 °C | 
| Storage and transport temperature, maximum | +85 °C | 
| Restistance to shock | 30 g / 11 ms | 
| Protection rating | 0 | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC | 
| Rated impulse withstand voltage Uimp | 0.8 kV | 
| Overvoltage category | III | 
| Degree of pollution to VDE 0100 | 3 | 
Electrical data
| Voltage type | DC (direct current) | 
| No-load supply current I0 | 100 mA | 
| Rated operating voltage, minimum | 20.4 VDC | 
| Rated operating voltage, maximum | 26.4 VDC | 
| Operating current | 2,100 mA | 
| Required rated short-circuit current to EN 60947-5-1 | 100 A | 
| Switching frequency, approx. | 1 Hz | 
Electrical data - Fail-safe digital outputs
| Rated operating current (safety outputs) | 1,000 mA | 
| Output current, (fail-safe output), maximum | 1 A | 
| Versions | p-type | 
| Voltage drop Ud, maximum | 1 V | 
| Current leakage Ir | 0.5 mA | 
| Voltage, Utilisation category DC12 | 24 VDC | 
| Current, Utilisation category DC12 | 1 A | 
| Voltage, Utilisation category DC13 | 24 VDC | 
| Current, Utilisation category DC13 | 1 A | 
Electrical data - Diagnostic output
| Operating current | 150 mA | 
| Versions | p-type | 
| Voltage drop Ud, maximum | 2 V | 
Electrical data - Electromagnetic compatibility (EMC)
| Interfering radiation | IEC 61000-6-4 | 
| EMC rating | IEC 60947-3 | 
Status indication
| Note (LED switching conditions display) | Multi-coloured LED: Green, Red LED yellow: Operating condition LED green: Supply voltage LED red: Fault | 
Scope of delivery
| Included in delivery | Actuators must be ordered separately. | 
Accessory
| Recommendation (actuator) | RST16-1 RST-U-2 | 
| Recommended safety switchgear | PROTECT PSC1 SRB-E-301ST SRB-E-201LC | 
 
                



 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  