- Individual coding with RFID technology
- Coding level 'High' according to ISO 14119
- 1 x connector plug M8
- Frontal and lateral actuation enabled
- Max. 31 sensors can be wired in series.
- Thermoplastic enclosure
- Simple mounting without additional angle
- RFID-technology for needs-based protection against tampering
Ordering data
| Product type description | RSS260-I1-SD-ST | 
| Article number (order number) | 103003604 | 
| EAN (European Article Number) | 4030661436456 | 
| eCl@ss number, Version 9.0 | 27-27-24-03 | 
| eCl@ss number, Version 11.0 | 27-27-24-03 | 
Approval - Standards
| Certificates | TÜV cULus EAC FCC IC | 
General data
| Standards | IEC 60947-5-3 | 
| general information | Individual coding | 
| Coding level according to ISO 14119 | High | 
| Active principle | RFID | 
| Housing construction form | Block | 
| Installation conditions (mechanical) | not flush | 
| Sensor topology | Sensor for series wiring | 
| Enclosure material | Plastic, thermoplastic, self-extinguishing | 
| Active area | Glass-fibre, thermoplastic | 
| Gross weight | 54 g | 
| Time to readiness, maximum | 2,000 ms | 
| Reaction time, maximum | 100 ms | 
| Duration of risk, maximum | 200 ms | 
General data - Features
| Serial diagnostics | Yes | 
| Diagnostic output | Yes | 
| Short circuit detection | Yes | 
| Short-circuit recognition | Yes | 
| Safety functions | Yes | 
| Cascadable | Yes | 
| Integral System Diagnostics, status | Yes | 
| Number of LEDs | 3 | 
| Number of semi-conductor outputs with signaling function | 1 | 
| Number of fail-safe digital outputs | 2 | 
| Number of Series-wiring of sensors | 31 | 
Safety appraisal
| Standards | EN ISO 13849-1 IEC 60947-5-3 EN 62061 IEC 61508 | |
| Performance level, up to | e | |
| Control category to EN13849 | 4 | |
| PFH-value | 6.80 x 10⁻¹⁰ /h | |
| 
 | 3 | |
| Mission Time | 20 Year(s) | 
Mechanical data
| Actuating panels | lateral front side | 
| Active area | lateral front | 
| Hysteresis (Switch distance), maximum | 2 mm | 
| Repeat accuracy R R | 0.5 mm | 
| Note (Repeat accuracy R) | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance between two sensor systems 100 mm | 
| Mounting | A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws. | 
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance Sn | front 12 mm lateral 9 mm | 
| Ensured switching distance ON, front | 10 mm | 
| Ensured switching distance OFF, front | 18 mm | 
| Ensured switching distance ON, side | 6 mm | 
| Ensured switch distance OFF Sar, lateral | 15 mm | 
Mechanical data - Connection technique
| Terminal Connector | Connector M8 | 
| Note | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current | 
Mechanical data - Dimensions
| Length of sensor | 29.5 mm | 
| Width of sensor | 39.2 mm | 
| Height of sensor | 18 mm | 
Ambient conditions
| Degree of protection | IP65 to EN 60529 IP67 to EN 60529 | 
| Ambient temperature, minimum | -25 °C | 
| Ambient temperature, maximum | +65 °C | 
| Storage and transport temperature, minimum | -25 °C | 
| Storage and transport temperature, maximum | +85 °C | 
| Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm | 
| Restistance to shock | 30 g / 11 ms | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC | 
| Rated impulse withstand voltage Uimp | 0.8 kV | 
| Overvoltage category | III | 
| Degree of pollution to VDE 0100 | 3 | 
Electrical data
| Voltage type | DC (direct current) | 
| No-load supply current I0 | 100 mA | 
| Rated operating voltage | 24 VDC -15% / +10% | 
| Rated operating voltage, minimum | 20.4 VDC | 
| Rated operating voltage, maximum | 26.4 VDC | 
| Operating current | 600 mA | 
| Required rated short-circuit current to EN 60947-5-1 | 100 A | 
| Switching frequency, approx. | 1 Hz | 
Electrical data - Fail-safe digital outputs
| Versions | p-type | 
| Voltage drop Ud, maximum | 1 V | 
| Current leakage Ir | 0.5 mA | 
| Voltage, Utilisation category DC12 | 24 VDC | 
| Current, Utilisation category DC12 | 0.25 A | 
| Voltage, Utilisation category DC13 | 24 VDC | 
| Current, Utilisation category DC13 | 0.25 A | 
Electrical data - Diagnostic output
| Operating current | 150 mA | 
| Versions | p-type | 
| Voltage drop Ud, maximum | 2 V | 
Electrical data - Electromagnetic compatibility (EMC)
| Interfering radiation | IEC 61000-6-4 | 
| EMC rating | IEC 60947-3 | 
Status indication
| Note (LED switching conditions display) | LED yellow: Operating condition LED green: Supply voltage LED red: Fault | 
Pin assignment
| PIN 1 | A1 Ue: White | 
| PIN 2 | X1 safety input 1: Brown | 
| PIN 3 | A2 GND: Green | 
| PIN 4 | Y1 safety output 1: Yellow | 
| PIN 5 | serial diagnostic output OUT Grey | 
| PIN 6 | X2 safety input 2: Pink | 
| PIN 7 | Y2 safety output 2: Blue | 
| PIN 8 | IN serial diagnostic input Pink | 
Accessory
| Recommendation (actuator) | RST16-1 RST-U-2 RST260-1 | 