- Power to lock
- Thermoplastic enclosure
- Max. length of the sensor chain 200 m
- Self-monitoring series-wiring
- Coding in accordance to ISO 14119 by using RFID-Technology
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
- Suitable for hinged and sliding guards
- Intelligent diagnosis
- Manual release
- Protection class IP66, IP67
- High holding force 2000
- symmetrical construction form, assembly on 40mm profiles
- OSSD safety outputs
- Emergency exit / Emergency release suitable for retrofitting
Ordering data
| Product type description | AZM201Z-ST2-T-SD2P-A | 
| Article number (order number) | 103032732 | 
| EAN (European Article Number) | 4030661529424 | 
| eCl@ss number, Version 9.0 | 27-27-26-03 | 
| eCl@ss number, Version 11.0 | 27-27-26-03 | 
Approval - Standards
| Certificates | TÜV cULus EAC FCC IC | 
General data
| Standards | IEC 60947-5-1 EN ISO 13849-1 IEC 61508 IEC 60947-5-3 EN ISO 14119 IEC 62061 | |
| general information | Universal coding | |
| Coding level according to ISO 14119 | Low | |
| Active principle | RFID | |
| Enclosure material | Glass-fibre, reinforced thermoplastic | |
| Gross weight | 596.1 g | |
| Time to readiness, maximum | 4,000 ms | |
| Duration of risk, maximum | 200 ms | |
| 
 | 100 ms | |
| 
 | 0.5 ms | 
General data - Features
| Guard locking monitored | Yes | 
| Serial diagnostics | Yes | 
| Manual release | Yes | 
| Short circuit detection | Yes | 
| Short-circuit recognition | Yes | 
| Series-wiring | Yes | 
| Safety functions | Yes | 
| Integral System Diagnostics, status | Yes | 
| Number of safety contacts | 2 | 
| Number of Series-wiring of sensors | 31 | 
Safety appraisal
| Standards | EN ISO 13849-1 IEC 62061 IEC 61508 | 
Safety appraisal - Interlocking
| Performance level, up to | e | 
| Control category | 4 | 
| PFH-value | 1.90 x 10⁻⁹ /h | 
| PFD value | 1.60 x 10⁻⁴ | 
| Safety Integrity Level (SIL), suitable for applications in | 3 | 
| Mission Time | 20 Year(s) | 
Safety appraisal - Guard locking
| Mission Time | 20 Year(s) | 
Mechanical data
| Mechanical life, minimum | 1,000,000 Operations | 
| Clamping force in accordance with ISO14119 Fzh | 2,000 N | 
| Clamping force, maximum Fmax | 2,600 N | 
| Latching force | 30 N | 
| Actuating speed, maximum | 0.2 m/s | 
Mechanical data - Connection technique
| Terminal Connector | Connector M12, 8-pole | 
Mechanical data - Dimensions
| Length of sensor | 50 mm | 
| Width of sensor | 40 mm | 
| Height of sensor | 220 mm | 
Ambient conditions
| Degree of protection | IP66 to EN 60529 IP67 to EN 60529 | 
| Ambient temperature, minimum | -25 °C | 
| Ambient temperature, maximum | +60 °C | 
| Storage and transport temperature, minimum | -25 °C | 
| Storage and transport temperature, maximum | +85 °C | 
| Relative humidity, minimum | 30 % | 
| Relative humidity, maximum | 95 % | 
| Note (Relative humidity) | non-condensing | 
| Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm | 
| Restistance to shock | 30 g / 11 ms | 
| Protection rating | III | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC | 
| Rated impulse withstand voltage Uimp | 0.8 kV | 
| Overvoltage category | III | 
| Degree of pollution to VDE 0100 | 3 | 
Electrical data
| Operating voltage, minimum | 20.4 VDC | 
| Operating voltage, maximum | 26.4 VDC | 
| No-load supply current I0 | 50 mA | 
| Current consumption with solenoid ON, average | 200 mA | 
| Current consumption with solenoid ON, peak | 700 mA / 100 ms | 
| Operating current | 1,200 mA | 
| Switching frequency, approx. | 1 Hz | 
Electrical data - Solenoid control
| Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) | 
| Classification ZVEI CB24I, Sink | C0 | 
| Classification ZVEI CB24I, Source | C1 C2 C3 | 
Electrical data - Fail-safe digital inputs
| Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) | 
| Classification ZVEI CB24I, Sink | C1 | 
| Classification ZVEI CB24I, Source | C1 C2 C3 | 
Electrical data - Fail-safe digital outputs
| Rated operating current (safety outputs) | 250 mA | 
| Voltage drop Ud, maximum | 4 V | 
| Current leakage Ir | 0.5 mA | 
| Voltage, Utilisation category DC13 | 24 VDC | 
| Current, Utilisation category DC13 | 0.25 A | 
| Classification ZVEI CB24I, Source | C2 | 
| Classification ZVEI CB24I, Sink | C1 C2 | 
Electrical data - Diagnostic output
| Operating current | 50 mA | 
| Voltage drop Ud, maximum | 4 V | 
| Voltage, Utilisation category DC13 | 24 VDC | 
| Current, Utilisation category DC13 | 0.05 A | 
Status indication
| Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green | 
Pin assignment
| PIN 1 | A1 Supply voltage UB | 
| PIN 2 | X1 Safety input 1 | 
| PIN 3 | A2 GND | 
| PIN 4 | Y1 Safety output 1 | 
| PIN 5 | OUT serial diagnostic output | 
| PIN 6 | X2 Safety input 2 | 
| PIN 7 | Y2 Safety output 2 | 
| PIN 8 | IN serial diagnostic input | 
Scope of delivery
| Included in delivery | Actuators must be ordered separately. Triangular key for AZM 201 | 
Accessory
| Recommendation (actuator) | AZ/AZM201-B1 AZ/AZM201-B30 | 
Notes
| Note (General) | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. | 
 
                

 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  