- Thermoplastic enclosure
- Coding in accordance to ISO 14119 by using RFID-Technology
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
- Suitable for hinged and sliding guards
- Intelligent diagnosis
- Manual release
- Protection class IP66, IP67
- High holding force 2000
- 2 OSSD safety outputs for guard door monitoring
- 2 OSSD safety outputs for guard locking monitoring
- symmetrical construction form, assembly on 40mm profiles
- Emergency exit / Emergency release suitable for retrofitting
Ordering data
| Product type description | AZM201D-ST2-T-1P2P2P |
| Article number (order number) | 103026879 |
| EAN (European Article Number) | 4030661555515 |
| eCl@ss number, Version 9.0 | 27-27-26-03 |
| eCl@ss number, Version 11.0 | 27-27-26-03 |
Approval - Standards
| Certificates | TÜV cULus EAC FCC IC |
General data
| Standards | EN ISO 13849-1 IEC 61508 IEC 60947-5-3 EN ISO 14119 IEC 62061 | |
| general information | Universal coding | |
| Coding level according to ISO 14119 | Low | |
| Active principle | RFID | |
| Enclosure material | Glass-fibre, reinforced thermoplastic | |
| Gross weight | 588 g | |
| Time to readiness, maximum | 4,000 ms | |
| Duration of risk, maximum | 200 ms | |
| 100 ms | |
| 0.5 ms |
General data - Features
| Power to unlock | Yes |
| Actuator monitored | Yes |
| Guard locking monitored | Yes |
| Manual release | Yes |
| Short circuit detection | Yes |
| Short-circuit recognition | Yes |
| Safety functions | Yes |
| Integral System Diagnostics, status | Yes |
| Number of safety contacts | 4 |
Safety appraisal
| Standards | EN ISO 13849-1 IEC/EN 62061 IEC 61508 |
Safety appraisal - Interlocking
| Performance level, up to | e |
| Control category | 4 |
| PFH-value | 5.70 x 10⁻¹⁰ /h |
| PFD value | 5.00 x 10⁻⁵ |
| Safety Integrity Level (SIL), suitable for applications in | 3 |
| Mission Time | 20 Year(s) |
Safety appraisal - Interlocking 2
| Performance Level, up to | d |
| Control category | 3 |
| Safety Integrity Level (SIL), suitable for applications in | 2 |
| Mission time | 20 Year(s) |
Safety appraisal - Guard locking
| Mission Time | 20 Year(s) |
Mechanical data
| Mechanical life, minimum | 1,000,000 Operations |
| Clamping force in accordance with ISO14119 Fzh | 2,000 N |
| Clamping force, maximum Fmax | 2,600 N |
| Latching force | 30 N |
| Actuating speed, maximum | 0.2 m/s |
Mechanical data - Connection technique
| Terminal Connector | Connector M12, 8-pole |
Mechanical data - Dimensions
| Length of sensor | 50 mm |
| Width of sensor | 40 mm |
| Height of sensor | 220 mm |
Ambient conditions
| Degree of protection | IP66 to EN 60529 IP67 to EN 60529 |
| Ambient temperature, minimum | -25 °C |
| Ambient temperature, maximum | +60 °C |
| Storage and transport temperature, minimum | -25 °C |
| Storage and transport temperature, maximum | +85 °C |
| Relative humidity, minimum | 30 % |
| Relative humidity, maximum | 95 % |
| Note (Relative humidity) | non-condensing |
| Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm |
| Restistance to shock | 30 g / 11 ms |
| Protection rating | III |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC |
| Rated impulse withstand voltage Uimp | 0.8 kV |
| Overvoltage category | III |
| Degree of pollution to VDE 0100 | 3 |
Electrical data
| Operating voltage, minimum | 20.4 VDC |
| Operating voltage, maximum | 26.4 VDC |
| No-load supply current I0 | 50 mA |
| Current consumption with solenoid ON, peak | 700 mA / 100 ms |
| Operating current | 1,200 mA |
| Switching frequency, approx. | 1 Hz |
Electrical data - Solenoid control
| Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
| Classification ZVEI CB24I, Sink | C0 |
| Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Fail-safe digital inputs
| Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
| Classification ZVEI CB24I, Sink | C1 |
| Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Fail-safe digital outputs
| Rated operating current (safety outputs) | 250 mA |
| Voltage drop Ud, maximum | 4 V |
| Current leakage Ir | 0.5 mA |
| Voltage, Utilisation category DC13 | 24 VDC |
| Current, Utilisation category DC13 | 0.25 A |
| Note, Utilisation category DC13 | Gilt für die Ausgänge Y1 und Y2 |
| Classification ZVEI CB24I, Source | C2 |
| Classification ZVEI CB24I, Sink | C1 C2 |
Electrical data - Diagnostic output
| Operating current | 100 mA |
| Voltage drop Ud, maximum | 4 V |
| Voltage, Utilisation category DC13 | 24 VDC |
| Current, Utilisation category DC13 | 0.05 A |
Status indication
| Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Pin assignment
| PIN 1 | A1 Supply voltage UB |
| PIN 2 | ELEC_DATA_CONNECTOR_1_PIN_ASSIGNMENT_2OUT |
| PIN 3 | A2 GND |
| PIN 4 | Y1 Safety output 1 |
| PIN 5 | ELEC_DATA_CONNECTOR_1_PIN_ASSIGNMENT_5Y3 |
| PIN 6 | ELEC_DATA_CONNECTOR_1_PIN_ASSIGNMENT_6Y4 |
| PIN 7 | Y2 Safety output 2 |
| PIN 8 | IN Solenoid control |
Scope of delivery
| Included in delivery | Actuators must be ordered separately. Triangular key for AZM 201 |
Accessory
| Recommendation (actuator) | AZ/AZM201-B1 AZ/AZM201-B30 |
Notes
| Note (General) | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |
| Note (Actuator monitored) | Safety outputs Y1, Y2 |
| Note (Guard locking monitored) | Safety outputs Y3, Y4 |