- Monitoring two-hand control panels to EN ISO 13851
- 2 safety contacts, STOP 0
- 1 Signalling output
Ordering data
| Product type description | SRB201ZH 24VDC | 
| Article number (order number) | 101163440 | 
| EAN (European Article Number) | 4250116201587 | 
| eCl@ss number, Version 9.0 | 27-37-18-19 | 
| eCl@ss number, Version 11.0 | 27-37-18-19 | 
| ETIM number, version 6.0 | EC001449 | 
| Available until | 31.12.2022 | 
Approval - Standards
| Certificates | TÜV cULus EAC TILVA | 
General data
| Standards | IEC 61508 IEC/EN 60204-1 EN 60947-5-1 EN ISO 13849-1 | 
| Climatic stress | EN 60068-2-78 | 
| Enclosure material | Glass-fibre reinforced thermoplastic, ventilated | 
| Material of the contacts, electrical | AgSn0. self-cleaning, positive drive | 
| Gross weight | 250 g | 
General data - Features
| Stop-Category | 0 | 
| Electronic Fuse | Yes | 
| Wire breakage detection | Yes | 
| Short-circuit recognition | Yes | 
| Removable Terminals | Yes | 
| Feedback circuit | Yes | 
| Automatic reset function | Yes | 
| Earth connection detection | Yes | 
| Integral System Diagnostics, status | Yes | 
| Number of auxiliary contacts | 1 | 
| Number of LEDs | 2 | 
| Number of openers | 2 | 
| Number of shutters | 2 | 
| Number of safety contacts | 2 | 
Safety appraisal
| Standards | EN 60947-5-1 EN ISO 13851 IEC 61508 | 
Safety appraisal - Relay outputs
| Performance level, stop 0, up to | e | 
| Category, Stop 0 | 4 | 
| Diagnostic Coverage (DC) Level, Stop 0 | ≥ 99 % | 
| PFH-Value Stop 0 | 2.00 x 10⁻⁸ /h | 
| Safety Integrity Level (SIL), Stop 0, suitable for applications in | 3 | 
| Mission time | 20 Year(s) | 
| Common Cause Failure (CCF), minimum | 65 | 
Mechanical data
| Mechanical life, minimum | 10,000,000 Operations | 
| Mounting | Snaps onto standard DIN rail to EN 60715 | 
Mechanical data - Connection technique
| Terminal Connector | Screw connection rigid or flexible | 
| Terminal designations | IEC/EN 60947-1 | 
| Cable section, minimum | 0.25 mm² | 
| Cable section, maximum | 2.5 mm² | 
| Tightening torque of Clips | 0.6 Nm | 
Mechanical data - Dimensions
| Width | 22.5 mm | 
| Height | 100 mm | 
| Depth | 121 mm | 
Ambient conditions
| Degree of protection of the enclosure | IP40 | 
| Degree of protection of the mounting space | IP54 | 
| Degree of protection of clips or terminals | IP20 | 
| Ambient temperature, minimum | -25 °C | 
| Ambient temperature, maximum | +60 °C | 
| Storage and transport temperature, minimum | -40 °C | 
| Storage and transport temperature, maximum | +85 °C | 
| Resistance to vibrations to EN 60068-2-6 | 10...55 Hz, Amplitude 0.35 mm, ± 15 % | 
| Restistance to shock | 30 g / 11 ms | 
Ambient conditions - Insulation value
| Rated impulse withstand voltage Uimp | 4 kV | 
| Overvoltage category | III | 
| Degree of pollution to IEC/EN 60664-1 | 2 | 
Electrical data
| Frequency range | 50 Hz 60 Hz | 
| Rated operating voltage | 24 VAC -15% / +10% 24 VDC -15% / +20%, residual ripple max. 10 % | 
| Rated AC voltage for controls, 50 Hz, minimum | 20.4 VAC | 
| Rated control voltage at AC 50 Hz, maximum | 26.4 VAC | 
| Rated AC voltage for controls, 60 Hz, minimum | 20.4 VAC | 
| Rated control voltage at AC 60 Hz, maximum | 26.4 VAC | 
| Rated AC voltage for controls at DC minimum | 20.4 VDC | 
| Rated control voltage at DC, maximum | 28.8 VDC | 
| Electrical power consumption | 1.2 W | 
| Contact resistance, maximum | 0.1 Ω | 
| Note (Contact resistance) | in new state | 
| Drop-out delay in case of power failure, typically | 80 ms | 
| Drop-out delay in case of emergency, typically | 20 ms | 
| Pull-in delay at automatic start, maximum, typically | 100 ms | 
| Pull-in delay at RESET, typically | 20 ms | 
Electrical data - Safe relay outputs
| Voltage, Utilisation category AC15 | 230 VAC | 
| Current, Utilisation category AC-15 | 6 A | 
| Voltage, Utilisation category DC13 | 24 VDC | 
| Current, Utilisation category DC13 | 6 A | 
| Switching capacity, minimum | 10 VDC | 
| Switching capacity, minimum | 10 mA | 
| Switching capacity, maximum | 250 VAC | 
| Switching capacity, maximum | 8 A | 
Electrical data - Digital inputs
| Conduction resistance, maximum | 40 Ω | 
Electrical data - Relay outputs (auxiliary contacts)
| Switching capacity, maximum | 24 VDC | 
| Switching capacity, maximum | 2 A | 
Electrical data - Electromagnetic compatibility (EMC)
| EMC rating | EMC-Directive | 
Status indication
| Indicated operating states | Position relay K2 Position relay K1 | 
Other data
| Note (applications) | Two-hand control panels | 
Notes
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. | 
Circuit example
| Note (Wiring diagram) | Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. The wiring diagram is shown for the de-energised condition. The control recognises cross-short, cable break and earth leakages in the monitoring circuit. Button A and B: 1 NC contact / 1 NO contact (note: the NC contact of the buttons A and B must be opened, before the NO contact closes. No overlapping contacts to avoid triggering of fuse F1 and F2). (H2) = Feedback circuit Simultaneity monitoring 0.5 seconds | 
 
                



 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  