- 3 levels OFF-ON-OFF
- Thermoplastic enclosure
- 1 Cable entry M 20 x 1.5
- Good resistance to oil and petroleum spirit
- Particularly fit for robot applications in accordance with the ANSI Robotics Standard
- The redundant contact configuration enables signal processing using conventional safety relay modules
- Contacts do not close upon reset (level 3 ->, level 1)
Ordering data
| Product type description | ZSD5/O.LTG. | 
| Article number (order number) | 101199467 | 
| EAN (European Article Number) | 4030661521435 | 
| eCl@ss number, Version 9.0 | 27-37-12-38 | 
| eCl@ss number, Version 11.0 | 27-37-12-38 | 
| ETIM number, version 6.0 | EC002571 | 
| ETIM number, version 7.0 | EC002571 | 
Approval - Standards
| Certificates | cULus | 
General data
| Standards | IEC 60947-5-1 IEC 60204-1 EN 775 ISO 12100 ISO 11161 ISO 10218 UL508 1 CSA C22.2 Nr.14 JIS C8201-5-1 ANSI/RIA R15.06 | 
| Enclosure material | Plastic, thermoplastic, self-extinguishing | 
| Material of the contacts, electrical | Silver | 
| Gross weight | 190 g | 
General data - Features
| Number of openers | 1 | 
| Number of shutters | 2 | 
Mechanical data
| Note (Mechanical lifetime) | NO: | 
Mechanical data - Connection technique
| Terminal Connector | Screw connection | 
| Cable section, minimum | 0.14 mm² | 
| Cable section, maximum | 1.5 mm² | 
Ambient conditions
| Degree of protection | IP65 | 
| Ambient temperature, minimum | -10 °C | 
| Ambient temperature, maximum | +60 °C | 
Ambient conditions - Insulation value
| Rated impulse withstand voltage Uimp | 2.5 kV | 
Electrical data
| Rated operating voltage | 250 VAC 250 VDC | 
| Operating current | 3,000 mA | 
| Switching element | NO contact, NC contact | 
| Switching principle | Slow action | 
| Switching frequency | 1,200 /h | 
Accessory
| Recommended safety switchgear | SRB, 2-channel with cross-wire detection | 
Notes
| Note (General) | Customer-specific versions, with connecting cable, are available upon request. The monitoring module must offer the possibility of cross-wire monitoring. Only a double shielded cable is authorised as supply line. 1) If the device is to be used in a damp room, a suitable connection cable must be used. 1) This device has been tested for impact and fire resistance according to UL508. | 
 
                


 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  