- Screw connection
 - Ex-Zone 22
 - Thermoplastic enclosure
 - 130 mm x 114 mm x 30 mm
 - Clamping force 2000N
 - 6 Contacts
 - Manual release
 - Interlock with protection against incorrect locking.
 - cable entries 4 M 16 x 1.5
 
Ordering data
| Product type description |   EX-AZM 161SK-12/12RKA-024-3D  |  
| Article number (order number) |   101187045  |  
| EAN (European Article Number) |   4030661334080  |  
| eCl@ss number, Version 9.0 |   27-27-26-03  |  
| eCl@ss number, Version 11.0 |   27-27-26-03  |  
Explosion protection
| Explosion protection: regulations |   EN 60079-0 EN 60079-31 EN 60947-5-1  |  
| Explosion protection designation |   D II 3D Ex tc IIIC T80°C Dc X  |  
Manufacturer declaration  |    ATEX Zone 22  |  
General data
| Standards |   EN 60947-5-1  |  
| Active principle |   electromechanical  |  
| Enclosure material |   Plastic, glass-fibre reinforced thermoplastic, self-extinguishing  |  
| Material of the contacts, electrical |   Silver  |  
| Gross weight |   475 g  |  
General data - Features
| Power to lock |   Yes  |  
| Manual release |   Yes  |  
| Number of actuating directions |   3  |  
| Number of auxiliary contacts |   2  |  
| Number of safety contacts |   4  |  
Safety appraisal
| Standards |   EN ISO 13849-1  |  
| Mission Time |   20 Year(s)  |  
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) |   2,000,000 Operations  |  
Mechanical data
| Mechanical life, minimum |   1,000,000 Operations  |  
| Actuating play in direction of actuation |   5.5 mm  |  
| Impact energy, maximum |   1 J  |  
| Latching force |   30 N  |  
| positive break travel |   10 mm  |  
| Positive break force, minimum |   20 N  |  
| Actuating speed, maximum |   1 m/s  |  
Mechanical data - Connection technique
| Terminal Connector |   Screw connection  |  
| Cable cross-section of the cable glands, minimum |   5 mm  |  
| Cable cross-section of the cable glands, maximum |   10 mm  |  
| Cable section, minimum |   1 x 0.75 mm²  |  
| Cable section, maximum |   1 x 1.5 mm²  |  
| Note (Cable section) |   All indications about the cable section are including the conductor ferrules.  |  
Mechanical data - Dimensions
| Length of sensor |   30 mm  |  
| Height of sensor |   114 mm  |  
Ambient conditions
| Degree of protection |   IP67  |  
| Ambient temperature, minimum |   -10 °C  |  
| Ambient temperature, maximum |   +50 °C  |  
Ambient conditions - Insulation value
| Rated insulation voltage Ui |   250 V  |  
| Rated impulse withstand voltage Uimp |   4 kV  |  
Electrical data
| Rated control voltage |   24 VAC  |  
| Rated control voltage |   24 VDC  |  
| Utilisation category AC-15 |   230 VAC  |  
| Utilisation category AC-15 |   4 A  |  
| Utilisation category DC-13 |   24 VDC  |  
| Utilisation category DC-13 |   2.5 A  |  
| Electrical power consumption, maximum |   10 W  |  
| Switching element |   NO contact, NC contact  |  
| Switching principle |   Creep circuit element  |  
| Switching frequency |   1,000 /h  |  
Electrical data - Safety contacts
| Current, Utilisation category AC-15 |   4 A  |  
| Current, Utilisation category DC13 |   2.5 A  |  
Electrical data - Auxiliary contacts
| Current, Utilisation category AC-15 |   4 A  |  
| Current, Utilisation category DC13 |   2.5 A  |  
Scope of delivery
| Included in delivery |   Actuators must be ordered separately. Including Ex-certified screwed cable gland and screw plug  |  
Notes
| Note (Manual release) |   For maintenance, installation, etc. For manual release using M5 triangular key, available as accessory  |  
                