- 1 Cable entry M 20 x 1.5
- Ex-Zone 22
- Metal enclosure
- Actuator shaft can be turned 360°
- Actuator heads can be repositioned by 4 x 90°
- 40,5 mm x 107 mm x 65,3 mm
- Good resistance to oil and petroleum spirit
- Ex certified
Ordering data
| Product type description | EX-TV10S 335-11Z-3D |
| Article number (order number) | 101193005 |
| EAN (European Article Number) | 4030661354705 |
| eCl@ss number, Version 9.0 | 27-27-06-09 |
| eCl@ss number, Version 11.0 | 27-27-06-09 |
| ETIM number, version 6.0 | EC002591 |
| ETIM number, version 7.0 | EC002591 |
Explosion protection
| Explosion protection: regulations | EN 60079-31 IEC 60079-0 |
| Explosion protection zones | 22 |
| Explosion protection category | 3D |
| Explosion protection designation | D II 3D Ex tc IIIC T90°C Dc X |
General data
| Standards | EN 60947-5-1 BG-GS-ET-15 |
| Enclosure material | Light alloy die-casting |
| Enclosure coating material | painted |
| Material of the actuator | Stainless steel |
| Material of the contacts, electrical | Silver |
| Gross weight | 378.5 g |
General data - Features
| Number of auxiliary contacts | 1 |
| Number of safety contacts | 1 |
Safety appraisal
| Standards | EN ISO 13849-1 |
| Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) | 20,000,000 Operations |
Mechanical data
| Actuating element | Other |
| Mechanical life, minimum | 1,000,000 Operations |
| Positive break angle | 7 ° |
| Mounting hole for the Shaft | 10 mm |
| Impact energy, maximum | 4 J |
| positive break travel | 10.7 mm |
| Positive break force, minimum | 5 N |
| Note (Positive break force) | per NC |
| Actuating speed, maximum | 1 m/s |
| Positive break torque | 0.6 Nm |
Mechanical data - Connection technique
| Terminal Connector | Screw connection |
| Cable section, minimum | 0.75 mm² |
| Cable section, maximum | 2.5 mm² |
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data - Dimensions
| Length of sensor | 65.3 mm |
| Width of sensor | 40.5 mm |
| Height of sensor | 107 mm |
Ambient conditions
| Degree of protection | IP67 |
| Ambient temperature, minimum | -20 °C |
| Ambient temperature, maximum | +60 °C |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
| Thermal test current | 10 A |
| Utilisation category AC-15 | 230 VAC |
| Utilisation category AC-15 | 4 A |
| Utilisation category DC-13 | 24 VDC |
| Utilisation category DC-13 | 4 A |
| Switching element | NO contact, NC contact |
| Switching principle | Creep circuit element |
| Switching frequency | 1,000 /h |
Notes
| Note (General) | By turning the head in 90° steps, 8 actuating planes are possible. A Torx T10 screwdriver is required for this purpose. Even when the screw is removed, the head is self-retaining. The switch can still not be tampered. Adjustment tool: locking screw to fix, shaft pre-drilled to pin Universal joint available to compensate for axial displacement (only for shaft bore 10 mm) |