- Ex-Zone 1 and 21
- only for positioning tasks
- Metal enclosure
- Good resistance to oil and petroleum spirit
- 40,5 mm x 76 mm x 38 mm
- Actuator heads can be repositioned by 4 x 90°
- Ex-certified screwed cable gland
- Mounting details to EN 50041
- 1 Cable entry M 20 x 1.5
- Ex certified
Ordering data
| Product type description | EX-T4V10H335-02Y |
| Article number (order number) | 101212061 |
| EAN (European Article Number) | 4030661448688 |
| eCl@ss number, Version 9.0 | 27-27-26-01 |
| eCl@ss number, Version 11.0 | 27-27-26-01 |
| ETIM number, version 6.0 | EC000030 |
| ETIM number, version 7.0 | EC000030 |
Approval - Standards
| Certificates | cULus CCC CCC EX DEKRA DEKRA EX |
Explosion protection
| Explosion protection: regulations | EN 60079-0 EN 60079-1 EN 60079-31 EN 60079-7 EN 60947-5-1 |
| Explosion protection zones | 1 21 |
| Explosion protection category | 2D 2G |
| Explosion protection designation | D II 2G Ex d e IIC T6 Gb D II 2D Ex tb IIIC T80°C Db |
General data
| Standards | BG-GS-ET-15 |
| Housing construction form | Norm construction design |
| Enclosure material | Zinc die-cast |
| Enclosure coating material | painted |
| Material of the contacts, electrical | Silver |
| Lever material | Metal film |
| Material of the rod | Plastic |
| Gross weight | 400 g |
General data - Features
| Number of safety contacts | 2 |
Safety appraisal
| Standards | EN ISO 13849-1 |
| Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) | 20,000,000 Operations |
Mechanical data
| Actuating element | Rod lever |
| Mechanical life, minimum | 1,000,000 Operations |
| Impact energy, maximum | 7 J |
| Actuating speed, maximum | 2.5 m/s |
| Note (Actuating speed) | Actuating speed with actuating angle 30° to switch axis |
| Note (Switchover time) | Switchover time in accordance with actuating speed |
| Actuating torque, minimum | 0.3 Nm |
Mechanical data - Connection technique
| Terminal Connector | Screw connection |
| Cable cross-section of the cable glands, minimum | 7 mm |
| Cable cross-section of the cable glands, maximum | 12 mm |
| Cable section, minimum | 1 mm² |
| Cable section, maximum | 2.5 mm² |
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
| Wire cross-section | 13 AWG |
Mechanical data - Dimensions
| Length x Width x Height | Height of sensor: 111.5 mm (without rod) |
| Length of sensor | 38 mm |
| Width of sensor | 40.5 mm |
Ambient conditions
| Degree of protection | IP65 |
| Ambient temperature, minimum | -20 °C |
| Ambient temperature, maximum (Cable section 1mm2) | +50 °C |
| Ambient temperature, maximum (Cable section 2.5mm2) | +55 °C |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 250 V |
| Rated impulse withstand voltage Uimp | 4 kV |
Electrical data
| Thermal test current | 5 A |
| Switching element | Opener (NC) |
| Switching principle | Slow action |
| Bounce duration, maximum | 3 ms |
| Switching frequency | 1,800 /h |