- especially easy to clean through concealed threaded holes at the rear
- Explosion protection for ATEX Zones 2 and 22
- Stainless steel enclosure
- 88 mm x 27 mm x 14,5 mm
- Concealed mounting possible
- Insensitive to transverse misalignment
- no mechanical wear
- Suitable for food processing industry
- Cable connection suitable for the food industry
Ordering data
Product type description | EX-BNS 40S-12Z-C |
Article number (order number) | 103002174 |
EAN (European Article Number) | 4030661428475 |
eCl@ss number, Version 9.0 | 27-27-24-02 |
eCl@ss number, Version 11.0 | 27-27-24-02 |
ETIM number, version 6.0 | EC002544 |
ETIM number, version 7.0 | EC002544 |
Explosion protection
Explosion protection: regulations | EN 60079-15 EN 60079-31 IEC 60079-0 |
Explosion protection zones | 22 2 |
Explosion protection category | 3D 3G |
Explosion protection designation | D II 3G Ex nA nC IIC T6 Gc D II 3D Ex tc IIIC T80°C Dc X |
Manufacturer declaration | ATEX Zone 2 and 22 |
General data
Standards | IEC 60947-5-3 BG-GS-ET-14 |
Housing construction form | Block |
Installation conditions (mechanical) | not flush |
Enclosure material | Stainless steel (V4A) |
Gross weight | 200 g |
General data - Features
Coding | Yes |
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Concealed, threaded holes on the back | Yes |
Prerequisite evaluation unit | Yes |
Number of openers | 2 |
Number of shutters | 1 |
Safety appraisal
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
B10d- Value Normally-closed contact/Normally open contact (NC/NO) | 25,000,000 Operations |
Mechanical data
Active area | lateral |
Actuating element | Magnet |
Impact energy, maximum | 7 J |
Direction of motion | Head-on to the active surface |
Mechanical data - Switching distances according IEC 60947-5-3
Ensured switch distance ON Sao | 8 mm |
Ensured switch distance OFF Sar | 18 mm |
Mechanical data - Connection technique
Terminal Connector | Cable |
Length of cable | 1 m |
Wire cross-section | 0.25 mm2 |
Wire cross-section | 23 AWG |
Material of the Cable mantle | LiYY |
Mechanical data - Dimensions
Length of sensor | 14.5 mm |
Width of sensor | 88 mm |
Height of sensor | 27 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 IP67 to EN 60529 |
Ambient temperature, minimum | -20 °C |
Ambient temperature, maximum | +60 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +80 °C |
Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Electrical data
Voltage type | AC (alternating current) DC (direct current) |
Required rated short-circuit current to EN 60947-5-1 | 100 A |
Switching voltage, maximum | 24 VAC |
Switching voltage, maximum | 24 VDC |
Switching current, maximum | 0.25 A |
Switching capacity, maximum | 3 W |
Switching frequency, maximum | 5 Hz |
Electrical data - Digital Output
Versions | Miscellaneous, Reed contacts |
Scope of delivery
Included in delivery | Actuators must be ordered separately. |
Accessory
Recommendation (actuator) | BPS 40S-2 BPS 40S-1-C BPS 40S-2-C |
Recommended safety switchgear | SRB-E-301ST SRB-E-201LC |
Notes
Note (General) | Contact symbols shown for the closed condition of the guard device. The contact configuration for versions with or without LED is identical. |
Circuit example
Note (Wiring diagram) | Contact S21-S22 must be integrated in the safety circuit. |