Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Cable transducer - absoluteInterface CANopen® or CANopen® redundant
- Interface CANopen® or CANopen® redundant
- Potentiometer sensing measuring method
- Operating temperature -40...+85 °C
- Protection IP 65
- Flange connector M12 or cable
- Removable stickers for drainage
- Isolation voltage 3 kV
Technical data - electrical ratings
- Voltage supply
- 10...30 VDC
- Consumption typ.
- 25 mA (24 VDC, w/o load)
- Initializing time typ.
- 500 ms after power on
- Interface
- CANopen®
- Function
- Linear position feedback
- Profile conformity
- CANopen® CiA DS 301, DS 406, DS 410
- Measuring range
- Up to 8 m (linear position)
- 360° (inclination angle)
- Resolution
- 0,1 mm (linear position)
- 0,1 ° (inclination angle)
- Temperature coefficient
- 0,02 °/K (inclination angle)
- Linearity
- ±0.3 % FS (linear position)
- ±0.5 % FS (inclination angle)
- Absolute accuracy
- ±0,3 % FS (linear position)
- ±0,5 % FS (inclination angle)
- ±0,2 ° (+25 °C / inclination angle)
- Sensing method
- Potentiometer
- Code sequence
- Programmable
- Interference immunity
- DIN EN 61000-6-2
- Emitted interference
- DIN EN 61000-6-3
- Programmable parameters
- Operating modes
- Rotating direction
- Scaling
- Zero position
Technical data - mechanical design
- Protection DIN EN 60529
- IP 65 (housing, drainage holes closed)
- IP 54 (cable inlet)
- Material
- Cable: Stainless steel cable AISI 316 coated with nylon PA12
- Housing: plastic
- Operating temperature
- -40...+85 °C
- Measuring length
- 8 m
- Cable diameter
- 0,7 mm
- Cable fastening
- Eyelet Height: 5 mm Internal diameter: 5 mm Outer diameter: 10 mm
- Pull-in force
- >2,5 N (pull-in force reduced at low temperatures)
- Pull-out force
- ≤8 N
- Relative humidity
- 95 % non-condensing
- Resistance
- DIN EN 60068-2-6 Vibration 10 g, 10-2000 Hz
- DIN EN 60068-2-27 Shock 50 g, 11 ms
- Weight approx.
- 775 g
- Connection
- Cable 2 m, radial
- Flange connector M12, 5-pin
- Instruction
- Please consider the assembly instructions
Baumer_GCA8-12_SW.ZIP
Baumer_GCA8-PPxxx_RCN_xx0_A_xxx_stp_CAD.zip
Baumer_GCA8_CANopen_DS_EN.pdf
Baumer_GCA_BR_EN_1806_11203336_LRes.pdf
Baumer_GCA_CANopen_MA_BSIT_EN.pdf
Baumer_GCA8-PPxxx_RCN_xx0_A_xxx_stp_CAD.zip
Baumer_GCA8_CANopen_DS_EN.pdf
Baumer_GCA_BR_EN_1806_11203336_LRes.pdf
Baumer_GCA_CANopen_MA_BSIT_EN.pdf
Наш менеджер свяжется с вами в ближайшее время