Работаем с юридическими лицами, бюджетными организациями, ИП
            
        
                
                По вопросам приобретения товара пишите на zakaz@lanfor.ru
            
        
                Interface CANopen® 
                - Magnetic sensing method
- Resolution: 0.1 mm/step
- Interface CANopen®
- Measuring length up to 5 m
- Removable cabs for water outlet
- Extremely light thanks to housing of plastic and aluminium
- Available as redundant versions
Technical data - electrical ratings
- Voltage supply
- 10...30 VDC
 
- Consumption typ.
- 50 mA (24 VDC, w/o load)
 
- Initializing time
- ≤500 ms (not redundant)
- ≤800 ms (redundant)
 
- Interface
- CANopen®
 
- Function
- Linear position feedback
 
- Profile conformity
- CANopen® CiA DSP 301, DSP 305, DS 406
 
- Resolution
- 0,1 mm/step
 
- Linearity
- ±0.61 % full scale output (f.s.o.)
 
- Absolute accuracy
- ±1,03 % f.s.o. (+25 °C)
- ±1,11 % f.s.o. (-40...+85 °C)
 
- Sensing method
- Magnetic
 
- Code
- Binary
 
- Code sequence
- Programmable
 
- Interference immunity
- DIN EN 61000-6-2
 
- Emitted interference
- DIN EN 61000-6-4
 
- Programmable parameters
- Operating modes
- Total resolution
- Scaling
 
- Diagnostic function
- Position or parameter error
- Multiturn sensing
 
Technical data - mechanical design
- Protection DIN EN 60529
- IP 65 (encoder)
 
- Material
- Encoder housing: aluminium
- Cable-pull housing: PA6 GF30
- Cable: Stainless steel cable coated with polyamide
 
- Operating temperature
- -40...+85 °C (not redundant)
- -40...+65 °C (redundant)
 
- Service life
- Typ. >500000 strokes
 
- Measuring length
- 5 m
 
- Cable acceleration
- ≤50 m/s²
 
- Cable diameter
- 0,61 mm
 
- Pull-in force
- >3 N
 
- Pull-out force
- ≤9 N
 
- Relative humidity
- 95 % temporary condensing
 
- Resistance
- DIN EN 60068-2-6 Vibration 10 g, 10-2000 Hz
- DIN EN 60068-2-27 Shock 50 g, 11 ms
 
- Weight approx.
- 600 g
 
- Connection
- Flange connector M12, 5-pin
- Cable 2 m
 
- Bending radius
- Cable: >55 mm
 
- Special characteristics
- Coated electronic
 
- Instruction
- Please consider the assembly instructions
 
                        
                        Baumer_BMMSK50_CANopen_DS_EN.pdf
Baumer_BMMS_DE_EN_FR_CoC_81162933.pdf
Baumer_BMMS_K_M_CANopen_II_A4_DE_EN_FR_IT_ES_81195825.pdf
Baumer_cable_transducer_BR_EN_1709_11191945_LRes.pdf
                    
                
            
            Baumer_BMMS_DE_EN_FR_CoC_81162933.pdf
Baumer_BMMS_K_M_CANopen_II_A4_DE_EN_FR_IT_ES_81195825.pdf
Baumer_cable_transducer_BR_EN_1709_11191945_LRes.pdf
                            Наш менеджер свяжется с вами в ближайшее время
                        
                     
                
 
                                         
                                         
                                         
                                         
                                         
                                         
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  