- 1 Cable entry M 20 x 1.5
- Metal enclosure
- Long life
- Universal coding
- 40,5 mm x 114 mm x 38 mm
- Actuator heads can be repositioned in steps 4 x 90°
- Can be mounted on a flat surface
- High level of contact reliability with low voltages and currents
- Slotted holes for adjustment, circular holes for location
Ordering data
| Note (Delivery capacity) | Not available! | 
| Product type description | AZ 335-12ZUEK | 
| Article number (order number) | 101159131 | 
| eCl@ss number, Version 9.0 | 27-27-26-02 | 
| eCl@ss number, Version 11.0 | 27-27-26-02 | 
General data
| Coding level according to ISO 14119 | Low | 
| Enclosure material | Aluminium | 
| Enclosure coating material | painted | 
| Material of the contacts, electrical | Silver | 
| Gross weight | 230 g | 
General data - Features
| Number of auxiliary contacts | 1 | 
| Number of safety contacts | 2 | 
Safety appraisal
| Standards | EN ISO 13849-1 | 
| Mission Time | 20 Year(s) | 
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) | 2,000,000 Operations | 
| B10d Normally open contact (NO) | 1,000,000 Operations | 
| Note (B10d Normally open contact (NO)) | at 10% Ie and ohmic load | 
Mechanical data
| Mechanical life, minimum | 10,000,000 Operations | 
| Latching force | 5 N | 
| positive break travel | 10.7 mm | 
| Positive break force, minimum | 5 N | 
| Note (Positive break force) | per NC | 
Mechanical data - Connection technique
| Terminal Connector | Screw connection | 
| Cable section, minimum | 0.75 mm² | 
| Cable section, maximum | 2.5 mm² | 
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. | 
Mechanical data - Dimensions
| Length of sensor | 38 mm | 
| Width of sensor | 40.5 mm | 
| Height of sensor | 114 mm | 
Ambient conditions
| Degree of protection | IP67 to EN 60529 | 
| Ambient temperature, minimum | -30 °C | 
| Ambient temperature, maximum | +90 °C | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 250 V | 
| Rated impulse withstand voltage Uimp | 4 kV | 
Electrical data
| Thermal test current | 10 A | 
| Utilisation category AC-15 | 230 VAC | 
| Utilisation category AC-15 | 4 A | 
| Utilisation category DC-13 | 24 VDC | 
| Utilisation category DC-13 | 4 A | 
| Switching element | NO contact, NC contact | 
| Switching principle | Slow action with overlapping contacts | 
Scope of delivery
| Included in delivery | Actuators must be ordered separately. | 
Notes
| Note (General) | By turning the head in 90° steps, 8 actuating planes are possible. A Torx T10 screwdriver is required for this purpose. Even when the screw is removed, the head is self-retaining. The switch can still not be tampered. | 
 
                





 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  