- Device version for connection to a Safety-Field-Box SFB
- connector plug M12, 8-pole
- Thermoplastic enclosure
- Double-insulated
- Interlock with protection against incorrect locking.
- 130 mm x 90 mm x 30 mm
- 6 Contacts
- Long life
Ordering data
| Product type description | AZM 161Z-ST1-FB-RT | 
| Article number (order number) | 103034787 | 
| EAN (European Article Number) | 4030661541761 | 
| eCl@ss number, Version 9.0 | 27-27-26-03 | 
| eCl@ss number, Version 11.0 | 27-27-26-03 | 
Approval - Standards
| Certificates | cULus EAC | 
General data
| Standards | EN 60947-5-1 BG-GS-ET-19 | 
| Coding level according to ISO 14119 | Low | 
| Active principle | electromechanical | 
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing | 
| Material of the contacts, electrical | Silver | 
| Gross weight | 467.1 g | 
General data - Features
| Power to unlock | Yes | 
| Emergency exit | Yes | 
| Number of actuating directions | 3 | 
| Number of auxiliary contacts | 1 | 
| Number of safety contacts | 2 | 
Safety appraisal
| Standards | EN ISO 13849-1 | 
| Mission Time | 20 Year(s) | 
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) | 2,000,000 Operations | 
| B10d Normally open contact (NO) | 1,000,000 Operations | 
Mechanical data
| Mechanical life, minimum | 1,000,000 Operations | 
| Actuating play in direction of actuation | 5.5 mm | 
| Clamping force in accordance with ISO14119 Fzh | 2,000 N | 
| Latching force | 30 N | 
| positive break travel | 10 mm | 
| Positive break force, minimum | 20 N | 
| Actuating speed, maximum | 2 m/s | 
Mechanical data - Connection technique
| Terminal Connector | Connector plug M12, 8-pole, (A-coding) | 
Mechanical data - Dimensions
| Length of sensor | 30 mm | 
| Width of sensor | 130 mm | 
| Height of sensor | 90 mm | 
Ambient conditions
| Degree of protection | IP67 to EN 60529 | 
| Ambient temperature, minimum | -25 °C | 
| Ambient temperature, maximum | +60 °C | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | Connector, 8 poles - 60 V | 
| Rated impulse withstand voltage Uimp | 0.8 kV | 
| Rated impuls withstand voltage, connector 8-pole | 0.8 kV | 
Electrical data
| Thermal test current | 2 A | 
| Rated control voltage | 24 VAC/DC | 
| Required rated short-circuit current to EN 60947-5-1 | 1,000 A | 
| Electrical power consumption, maximum | 10 W | 
| Switching element | NO contact, NC contact | 
| Switching principle | Creep circuit element | 
| Switching frequency | 1,000 /h | 
Electrical data - Safety contacts
| Voltage, Utilisation category AC15 | 230 VAC | 
| Current, Utilisation category AC-15 | 4 A | 
| Voltage, Utilisation category DC13 | 24 VDC | 
| Current, Utilisation category DC13 | 2 A | 
Electrical data - Auxiliary contacts
| Voltage, Utilisation category AC15 | 230 VAC | 
| Current, Utilisation category AC-15 | 4 A | 
| Voltage, Utilisation category DC13 | 24 VDC | 
| Current, Utilisation category DC13 | 2 A | 
Other data
| Note (applications) | sliding safety guard removable guard hinged safety guard | 
Scope of delivery
| Included in delivery | Actuators must be ordered separately. | 
Notes
| Note (Emergency exit) | For cases of danger Actuation from within the hazardous area | 
 
                






 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  