Технические данные — электрические параметры | |
---|---|
Sensing method | Magnetic |
Resolution | 5 µm (4-times evaluation) 10 µm (4-times evaluation) 25 µm (4-times evaluation) |
Interpolation | 20 fold 50 fold 100 fold |
Output stages | HTL/push-pull TTL/RS422 |
Output signals | A+, B+, R+, A-, B-, R- |
Reference signal | Index signal, width 90° |
Output frequency | 350 kHz |
Short-circuit proof | Yes |
System accuracy | ±(0.02 mm + 0.04 mm x magnetic tape length (m)) |
Initializing time | 50 ms after power on (see general informations) |
Scan ratio | 40…60 % |
Interference immunity | DIN EN 61000-6-2 |
Emitted interference | DIN EN 61000-6-4 |
Approvals | CE UL |
Технические данные — механические параметры | |
Dimensions (sensor head) | 10 x 15 x 45.5 mm |
Protection DIN EN 60529 | IP 66 IP 67 |
Movement speed | |
Operating temperature | -40…+85 °C |
Working distance | 0.1…0.6 mm |
Resistance | DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms |
Material | Housing: zinc diecast, plated |
Relative humidity | EN 60068-2-78:2010 EN 60068-2-30:2005 93 % condensation permitted |
Connection | Cable 2 m Cable 0.3 m with connector M12 |
Weight approx. | 130 g |