Работаем с юридическими лицами, бюджетными организациями, ИП
            
        
                
                По вопросам приобретения товара пишите на zakaz@lanfor.ru
            
        
                Inclination sensors1-dimensional, measuring range 0...360° 
                - Size 52 mm
- MEMS capacitive measuring principle
- ISO 13849 compliant firmware
- E1 compliant design
- Interface CANopen®, SAE J1939, Analog
- Connection M12 and cable
- Protection up to IP 69K
Technical data - electrical ratings
- Voltage supply
- 8...36 VDC
 
- Reverse polarity protection
- Yes
 
- Consumption w/o load
- ≤40 mA (24 VDC)
 
- Initializing time
- ≤0,5 s after power on
 
- Interface
- CANopen®
- SAE J1939
- Analog (4...20 mA / 0.5...4.5 V / 0...5 V / 0...10 V)
 
- Load resistor
- ≥1 kΩ / voltage output
- ≤800 Ω / current output
 
- Measuring range
- 0...90°, 0...120°, 0...180°, 0...270°, 0...360°
 
- Resolution
- 0,1 ° CANopen®
- 0,1 ° SAE J1939
- 12 bit Analog
 
- Accuracy (+25 °C)
- Typ. ±0.1°
 
- Temperature coefficient
- 0,008 °/K
 
- Repeatability
- ± 0,1 ° (+25 °C)
 
- Sensing rate
- 1600 Hz
 
- Limit frequency
- 0.1...25 Hz, 2. order / low-pass filter (Default: 5 Hz)
 
- Interference immunity
- DIN EN 61000-6-2
- ECE Reg. No. 10R04
- ISO 7637-2
- ISO 11452-2 / ISO 11452-5
 
- Emitted interference
- DIN EN 61000-6-4
- ECE Reg. No. 10R04
- ISO 7637-2 / EN 55025
 
- Programmable parameters
- Preset and offset
- Filter
 
- Diagnostic function
- Parameter error
 
- Status indicator
- DUO-LED integrated in housing
 
- Approval
- UL approval / E63076
 
Technical data - mechanical design
- Dimensions W x H x L
- 48 x 24 x 52 mm
 
- Protection DIN EN 60529
- IP 66
- IP 67
- IP 68
- IP 69K
 
- Material
- Housing: aluminium, coated
 
- Corrosion protection
- IEC 60068-2-52 Salt mist
- for ambient conditions CX (C5-M) according to ISO 12944-2
 
- Operating temperature
- -40...+85 °C (see general information)
 
- Resistance
- DIN EN 60068-2-6 Vibration 20 g, 60-2000 Hz
- DIN EN 60068-2-27 Shock 200 g, 6 ms
 
- Weight approx.
- 95 g
 
- Connection
- Flange connector M12, 8-pin
- Flange connector M12, 5-pin
- Cable 1 m
 
- Instruction
- Use in safety functions exclusively based on Application Note and MTTFd reliability prediction (request separately).
 
                        
                        Baumer_GIM500R-1-dim_II_DE_EN_FR_IT_ES_81254208.pdf
Baumer_GIM500R-1-dim_V1_00_EDS_file_SW.zip
Baumer_GIM500R_1_dim_DS_EN.pdf
Baumer_GIM500R_DE-EN-FR_CoC_81230404.pdf
Baumer_GIM500R_SAEJ1939_MA_EN.pdf
Baumer_GIM500_1x_connector_M12_5pin_stp_CAD.zip
                    
                
            
            Baumer_GIM500R-1-dim_V1_00_EDS_file_SW.zip
Baumer_GIM500R_1_dim_DS_EN.pdf
Baumer_GIM500R_DE-EN-FR_CoC_81230404.pdf
Baumer_GIM500R_SAEJ1939_MA_EN.pdf
Baumer_GIM500_1x_connector_M12_5pin_stp_CAD.zip
                            Наш менеджер свяжется с вами в ближайшее время
                        
                     
                
 
                                         
                                         
                                         
                                         
                                         
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  